GDAU-004
Push-pull Gate-Drive Transformer...
5,00 €
109 In Stock
Menus
L (mH) Min | DCR (Ω) Max | Freq. (kHz) | Cres (pF) | Q x,y,z Min | Height (mm) | Width (mm) | Length (mm) | SRF (kHz) Min | Sensitivity (mV/uT) min |
---|---|---|---|---|---|---|---|---|---|
•Pulse transformer for battery management system
•Reinforced insulation at 3kV in pollution degree 2
•Creepage distance > 8mm
•ETmax product of 11Vµs across each half primary
•Maximum current 150mA
•Wide operating temperature range -40 to +125°C
•UL94 and RoHS materials
•AEC-Q200 qualified
•Weight : approx 2grams
•Tape&Reel packaging 13” W24mm
|
L1-3 (100kHz/10Vac) |
L4-6 (100kHz/10mVac) |
N1-2 : N2-3 : N6-5 : N5-4 |
DCR1-3 |
DCR4-6 |
RINS Prim/Sec (500Vdc) |
DWI Prim/Sec | |
---|---|---|---|---|---|---|---|
430µH ±25% |
713µH ±25% |
1:1:1.29:1.29 |
0.38Ω MAX |
0.38Ω MAX |
> 1GΩ |
3kVac (50Hz/1mA/1min) |