Push-pull Gate-Drive Transformer 1:1:1.3:1.3 2x11Vus - GDAU-004

Push-pull Gate-Drive Transformer 1:1:1.3:1.3 2x11Vus - GDAU-004

Lvalue: 430µH
Max Volt-Time product: 2x11Vµs
Turn-ratio: 1:1:1.3:1.3

Suitable for Automotive BMS in onboard battery chargers
Pulse transformer for battery management system
Reinforced insulation at 3kV in pollution degree 2
Creepage distance > 8mm
Maximum current 150mA
Wide operating temperature range -40 to +125°C
UL94 and RoHS materials
AEC-Q200 qualified
Weight: approx 2grams

insert_drive_fileData sheet (PDF)

Dielectric strength 3kVac (50Hz/1mA/1min)
Between Windings 500Vac (50Hz/3mA/1min)
INDUCTANCE at 25ºC 430µH ±25%/713µH ±25%
DC RESISTANCE at 25ºC 0.38Ω MAX
Turn-Ratio 1:1:1.29:1.29
RINS Prim/Sec (500Vdc) 1GΩ

No customer comments for the moment.

Write a review

GDAU-004 dimensions

GDAU-004 pad layout

GDAU-004 electrical diagram

109 Items

5,00 €

Request a quote
Tell us your needs and get answer from our expert in less than a day!
Get quote
Client reviews