Menus
L (mH) Min | DCR (Ω) Max | Freq. (kHz) | Cres (pF) | Q x,y,z Min | Height (mm) | Width (mm) | Length (mm) | SRF (kHz) Min | Sensitivity (mV/uT) min |
---|---|---|---|---|---|---|---|---|---|
130 |
> Medical and industrial applications
> DCM Flyback
> Input Voltage 300 to 400 Vdc
> Output Voltage (Sec 1 + Sec2) 25 Vdc / 1,80 A
> Auxiliary 15 Vdc / 5 mA
> Switching Frequency 130 kHz
> Operating temperature -50/+85°C
> Estimated Total Losses: (@ 100°C):
Copper losses (DC) 1,50 mW
Core losses 0,50 W
Total losses 2 W
MAG. INDUCTANCE at 25ºC L(1-3) |
LEAKAGE INDUCTANCE PRIM Llk (1,3 – 5,6 shorted) |
Isolation Betw. PRI - AUX (1-3, 4,5) and Sec (6,9) |
Isolation PRI (1,3) and CORE |
Isolation SEC (6,9) and CORE |
TURN RATIO (10kHz/1Vac) 1A+N1B) : N2 : N3 : N4 | |
---|---|---|---|---|---|---|
645 uH ± 10% |
7 uH MAX |
2kV (50/60Hz; 1 mA; 2 sec) |
1KV (50/60Hz; 1 mA; 2 sec) |
1KV (50/60Hz; 1 mA; 2 sec) |
32:3:2+4 |
Lvalue: 645uH
Power: 50W 130Hz
Turn-ratio: 32:3:2+4