FLYT-012 - Flyback Transformer DCM Prim:100-400V Sec:3x12V 80kHz

Product
L (mH) MinDCR (Ω) MaxFreq. (kHz)Cres (pF)Q x,y,z MinHeight (mm)Width (mm)Length (mm)SRF (kHz) MinSensitivity (mV/uT) min
80
Showing 1 - 1 of 1 item
Characteristics

Flyback Transformer DCM Prim:100-400V Sec:3x12V 80kHz 

APPLICATIONS

> Automotive EV/PHV AC/DC on-board battery chargers

FEATURES

> DCM Flyback
> THT mounting
> Weight: approx 37g

OPERATION

> Operating temperature -40/+125°C
> Switching frequency 80kHz
> Input Prim: 100-400V/0.6Arms/1.4Apk
> Output Sec1: 12V/1.5A; Sec2: 12V/0.4A; Sec3: 12V/0.1A
> Estimated Total Losses:
DC-Copper losses (Vin=100V/100°C) 0.8 W
Core losses (Vin=400V/132kHz/100°C) 0.13 W


MAG. INDUCTANCE at 25ºC

L(1-3) 

LEAKAGE INDUCTANCE

PRIM 

Llk (1-3)  

All Secondary shorted

Isolation

Betw. PRI (N1A, N1B) and SEC (N2,N3,N4)

Isolation

Between SEC-N2 and SEC-N3

Isolation

Between windings and core

TURN RATIO (10kHz/1Vac)

1A+N1B) : N2 : N3 : N4  

FLYT-012

436 uH  < 500 uH TYP < 567 uH Max

10 μH MAX

3000Vac (50/60Hz; 3 mA; 2 sec)

3000Vac (50/60Hz; 3 mA; 2 sec)

500Vac (50/60Hz; 3 mA; 2 sec)

32:5:5:5 

Dimensions

PAD LAYOUT

ELECTRICAL DIAGRAM

Others

Lvalue: 500uH

Power: 40W 80Hz

Turn-ratio: 32:5:5:5