BCBM-12.5KW-001 - 12kW 2:1 CLLC Bidirectional Transformer Natural Cooling

Product
L (mH) MinDCR (Ω) MaxFreq. (kHz)Cres (pF)Q x,y,z MinHeight (mm)Width (mm)Length (mm)SRF (kHz) MinSensitivity (mV/uT) min
Showing 1 - 1 of 1 item
Characteristics

12kW 2:1 CLLC Bidirectional Transformer Natural Cooling

Features

  • A total 12.5 kW part enclosed in a whole aluminum housing.

  • Operating temperature -40 to 150ºC
  • Primary Currnent 40Arms
  • Secundary Current 80Arms
  • Approx weight: 4710g

TURN RATIO

Primary Inductance

Secondary inductance

LEAKAGE INDUCTANCE 

DC Resistance

DIELECTRIC STRENGTH

BCBM-12.5KW-001

2:1

3400µH min

850µH min

1-2, 3-4 shorted

 119µH ± 5%

3- 4, 1-2 open

29.8µH ± 5%

1-2

20mΩ typ.

3-4

6mΩ typ

1500 Vac 50/60Hz (0.5mA; 1min*)

Dimensions

Packaging

CAD MODELS

PAD LAYOUT

ELECTRICAL DIAGRAM

SOLDERING

MEASUREMENT CONDITIONS