3DTX10 3D Coil Cube Rx sensor for VR/AR magnetic tracking system 17.4x15.2x13.9 mm

L (mH) MinDCR (Ω) MaxFreq. (kHz)Cres (pF)Q x,y,z MinHeight (mm)Width (mm)Length (mm)SRF (kHz) MinSensitivity (mV/uT) min
2013.915.217.4
Showing 1 - 1 of 1 item
Characteristics

Coil Cube Rx sensor for VR magnetic tracking system.

Features

Three axis magnetic antenna for magnetic tracking sensor systems. Very good performance/size ratio, with isotropic response. Used as emitter in VR/AR applications (gaming, etc.) and motion capture applications. Very low latency compared with other motion tracking technologies.


Characteristics

High axis symmetry (X,Y,Z), repeatability (very good isotropy) and accuracy (up to 5%
tolerances)
Magnetic Sensitivity: 3.8 mVpp / App / m @20kHz.
Mechanical Drop & Vibration compliant.
Mounting method: SMT (Taped & Reeled).
-20ºC to 85ºC Temperature Performance.
Multiple frequencies available (typ 60kHz, 125kHz, 134kHz).
According industry and safety standards: UL94-V0.

                              

Lx,y,z nom (µH)

Qx,y,z nom Frequency (kHz)SRFx,y,z (kHz) MinDCRx (Ω) MaxDCRy (Ω) MaxDCRz (Ω) MaxSensitivity (mVpp/App/m) Min
3DTX10-A-0100J   140/140/104  2.6/2.6/2.0 20 1 6.7 6.9 6.5 3.5

This chart is a reference guide for the most common required values at working frequency of 20kHz. Any other inductance value at LF or tighter tolerances can be provided. Please contact our sales department for any inquiry. Sensitivity measured with Helmholtz coils H=11.37
App/m @20kHz. Contact us for measurement specification.
SRF: Self-resonant frequency of the coil.

Dimensions

3DTX10 dimensions

PAD LAYOUT

3DTX10 pad layout

ELECTRICAL DIAGRAM

3DTX10 electrical diagram