Frequency (kHz) 125
Cres (pF) 330
Q x,y,z Min 18
Sensitivity x,y,z (mVpp/App/m) Min 70
Height (mm) 4.45
Width (mm) 11.6
Length (mm) 13.0
SRF x,y (kHz) Min 300
DCR z (Ω) Max 160
DCR x,y (Ω) Max 100
SRF z (kHz) Min 600
L x,y,z (mH) 4.91


 

  1. Rated Inductance LR: Measured at frequency fL, with impedance analyser WK3260 with 3MHz installed.
  2. Q Factor Qmin: Measured at frequency fL, with impedance analyser WK3260 with 3MHz installed.
  3. Self-resonance frequency fmin Measured at frequency fL, with impedance analyser WK3260 with 3MHz installed.
  4. DC resistance RmaxMeasured at 20ºC ambient temperature, measuring current <IR.
  5. Sensitivity: Measured with Helmholtz coils 5 turns, 160mm ∅, + waveform generator Agilent 33120A + oscilloscope Agilent 54622A. Contact PREMO RFID for complete measurement specification.

 