Gate-Drive Transformer 2:1 200Vus - GDAU-003

Gate-Drive Transformer 2:1 200Vus - GDAU-003

Lvalue: 5mH
Max Volt-Time product: 200Vµs
Turn-ratio: 2:1

Suitable for Automotive PFC stage in onboard battery chargers
Working voltage up to 500Vdc
Functional insulation at 500V
ETmax product of 200Vµs
Wide operating temperature range -40 to +105°C
UL94 and RoHS materials
AEC-Q200 qualified
Weight: approx 2grams

insert_drive_fileData sheet (PDF)

Between Windings 500Vac (50Hz/3mA/1min)
Leakage inductance (uH) 13µH MAX
INDUCTANCE at 25ºC 3mH ≤ 5mH TYP ≤ 7mH
DC RESISTANCE at 25ºC 1.2Ω MAX (0.98Ω TYP)/0.6Ω MAX (0.45Ω TYP)
Turn-Ratio 2:1
Cps 15pF MAX

No customer comments for the moment.

Write a review

GDAU-003 dimensions

GDAU-003 pad layout

121 Items

5,00 €

Request a quote
Tell us your needs and get answer from our expert in less than a day!
Get quote
Client reviews