CWP-0600 B2

CWP-0600 B2


This product is out of stock.

0,00 €

IDC (A) Max 80
Ip RMS (A) 0.50 - 60
Ip RMS (A) Max 270
Phase error tan Φ (º) < 3.7
Burden RB (Ω) 12.5
Burden Voltage VB (VRMS) 0.3
Centre Hole Ø (mm) 8.5/7

Dimensions for A housing:

 

 

Type A (MAX) B (MAX) C (MAX) D (MIN)
A1 30.5 29.0 15 5.0
A2 31.5 31.5 15 8.0
A3 35 35 19

9.0

 

 

Dimensions for B housing:

 

 

Type A (MAX) B (MAX) C (MAX) D (MIN) E (±0.1) F (±0.1) G (±0.1) H (±0.1) I (±0.1)
B1 25.5 25.5 12.0 6.0 13.0 7.62 21.59 1.27 0.00
B2 31.5 32.0 15.0 8.0 16.0 10.00 25.50 2.54 2.54
B3 34.5 34.5 15.0 11.5 17.3 10.16 27.94 2.54 2.54

 

 

Dimensions for C housing:

 

 

 

Type A (MAX) B (MAX) C (MAX) D (MIN)
C1 25.0 23.5 11.5 7.0

 

 

Tolerances ± 0.1 unless otherwise noted.

All dimensiones in mm.

 

 

  • Nsec = 2500 *Nsec = 2000
  • Ip primary-current range.
  • Ipmax max.permissible AC-primary current without saturation.
  • IDCmax max. DC-current value without saturation for class 1-counter (IEC 1036).
  • tan F max. phase error concerning of Ip.
  • RB burden resistance for 0.3V signal voltage at Ipmax.
  • VB burden voltage RB during max Ip.
  • Linearity better than <0.3% between 0.1A to Ip.
  • Amplitude error better than 1%.
  • Values in product list are referenced to 50 Hz measurements.
  • Dielectric strenght 2500 Vac/50 Hz/1 min.