EMC Filters - Three-Phase + Neutral Line Filters - FVTO-IV Three Phase with Neutral Double Stage Filters
Features:
General purpose filter
- For frequency converters / PDS.
- Footprint mounting.
- High attenuation.
- Small size.
General specifications
- Maximum operating voltage: 520Vac.
- Operating frequency: DC - 60Hz.
- Hipot test voltage:
- L/N-›PE: 3000Vac 2s.
- L-›N: 1300Vdc 2s.
- Li-›Lj: 2250Vdc 2s.
- Application class: HPF Acc. TO DIN 40040
- (-25ºC/+85ºC/95% RH, 30d).
- Flammability class: UL 94 V2.