Others - SMD Ferrite RF Chip Inductors - MO1210 Plastic Moulded Inductor High L (0.12uH-150uH)
Measurement conditions:
- Rated Inductance LR: Measured at frequency fL, with impedance analyser HP 4286A or HP 4287 and test fixture HP 16192A.
- Q Factor Qmin: Measured at frequency fQ, with impedance analyser HP 4286A or HP 4287 and test fixture HP 16192A.
- Rated current IR: Maximum permissible dc with an inductance decrease of ΔL/L0≤10% and/or temperature increase of ≤20ºC referred to 85ºC ambient temperature.
- Self-resonance frequency fres,min: Measured with network analyser HP 8753D and 1mm pad distance of CECC test fixture.
- DC resistance Rmax: Measured at 20ºC ambient temperature, measuring current <IR.