Mesure de courant - Hall-Effect Sensors - HCT-LP Closed Loop 1:2000
Caractéristiques:
Accurate measurements of variety of signal currents: DC, AC, pulsed, mixed.
- High electrical isolation between primary circuit (high current) and secondary circuit (electronic circuit).
- Overload capability.
- PCB mounting in small size.
- Closed loop solution with excellent accuracy.
- Very good linearity.
- Wide frequency bandwitdh.
General Data:
- Operating Temperature: -40 to +85ºC
- Storage Temperature: -40 to +125ºC
- Weight: 25 g.
- Compensation Winding Maximum Resistance (T=25ºC): 45 Ohm.
Accuracy:
- Accuracy at Ip (T=25ºC): < ±0.5%
- Linear Error (Full Scale, Vcc=
±15V, Rb=15 Ohm): < 0.1%
- Offset Current:
± 200uA Max.
- Offset Current Drift:
± 0.2 mA.
- Time Response (10% to 90% of Ip): < 1us.
- di/dt Followed Accurately: > 50A / us.
- Frequency Bandwidth: DC to 200kHz (-3 dB).
Applications:
- AC variable speed drives and servo motor drives.
- Battery supplied applications Uninterruptible Power Supplies (UPS).
- Static converters for DC motor drives.
- Switched Mode Power Supplies (SMPS).
- Power supplies for welding applications.