PG SERIES LAMINATED TRANSFORMERS

Transformateurs de puissance - Transformateurs 50/60hz - PG Series laminated transformers

Dimensions and Pad Layout:

  • EI30:

 

Series A1 ±0,5 A2 ±0,5 C ±0,5 D ±1,0 E ±0,1 F ±0,2 G ±0,5
EI30/5 32.6 27.6 15.2 4.0 SQ0.64 5.0 20.0
EI30/12.5 32.3 27.3 27.8 4.0 SQ0.64 5.0 20.0
EI30/15.5 32.6 27.6 27.8 4.0 SQ0.64 5.0 20.0
EI30/18 32.6 27.6 29.8 4.0 SQ0.64 5.0 20.0
EI30/23 32.6 27.6 34.3 4.0 SQ0.64 5.0 20.0

 

 

 

  • EI38:

 

Series A1 ±0,5 A2 ±0,5 C ±0,5 D ±1,0 E ±0,1 F ±0,2 G ±0,5
EI38/13.6 41.0 35.0 28.0 4.0 SQ0.64 5.0 25.0

 

 

 

  • EI42:

 

 

 

Series A1 ±1.0 A2 ±1.0 C ±1.0 D ±1,0 E ±0,1 F ±0,2 G ±0,5
EI42/14.8 44.0 37.0 31.5 4.0 SQ0.64 5.0 25.0

 

 

 

  • EI48:

 

 

 

 

Series A1 ±1.0 A2 ±1.0 C ±1.0 D ±1.0 E ±0,1 F ±0,2 G ±0,5 H ±1.0 I ±1.0 J min K ±0.2
EI48/16.8 51.0 43.0 34.5 4.0 SQ0.64 5.0 27.5 40.0 32.0 6.3 ø2,4

 

 

All dimensions in mm.