PBP19 SERIES - PLANAR CHOKES 19.81X19.56X7.4MM

Inductors / Chokes - Planar Inductors - PBP19 Series - Planar Chokes 19.81X19.56X7.4mm

Measurement Conditions:

  • All test data are referenced to 25°C ambient temperature. 
  • Continuous operating temperature range must be within -40°C/+125°C (ambient + self heating) under worst case conditions; exposure to 150°C peak is allowed according to IEC85 F thermal index for all raw materials used.
  • Circuit design, component placement, PCB tracks size and thickness, airfl ow and other cooling provisions all affect the part temperature rise.
  • It is suggested that the component be tested at the system level to verify its temperature after 30 minutes in the end application.
  • +/-10% MAX on -40°C/+125°C temperature range.
  • DC current that will cause an approximate ΔT of +50°C.